Skip to content
Hotel occupancy sensor switch (PIR / radar presence detection) on a wall
CERoHS
Answer Snapshot

Qualification facts buyers can extract quickly

Hotel occupancy sensor switch that powers the room by presence, not by card. PIR or mmWave detection, AC 180–250V, 30A, door-contact linkage. A hotel occupancy sensor switch and presence-detection switch for card-free room energy saving.

Last Updated
8/28/2026
Who it is for
Hotels wanting card-free room energy control, Integrators building presence-based guest-room automation
Use cases
Rooms where guests forget or lose the card, Meeting rooms and public spaces with walk-in occupancy, Tight energy saving via door-contact linkage
MOQ
500 pcs for standard models; negotiable for OEM/ODM
Lead time
Samples 7-10 days / Mass production 20-30 days
Certifications
CE, RoHS
Served markets
Worldwide (CE / RoHS certified)
Export context
Hotel occupancy sensor switch; presence-based room power with optional door-contact linkage
Next step
Send the room type and detection preference (PIR or mmWave) — we return an occupancy sensor switch SKU with the right hold time.

Product overview

What a hotel occupancy sensor switch does

A hotel occupancy sensor switch powers the room by detecting a person, not by reading a card. The occupancy sensor switch turns lights and AC on when someone enters and off after they leave — useful in rooms where guests lose the card, and in meeting rooms with walk-in traffic.

PIR vs mmWave presence-detection switch

A PIR occupancy sensor switch is low-cost and detects motion; an mmWave presence-detection switch detects still presence (breathing-level), so it does not power off on a sleeping guest. Both feed a 30A relay that controls the full room circuit.

  • Card-free — the hotel occupancy sensor switch needs no card to operate.
  • Detection choice — PIR for motion, mmWave for still-occupancy.
  • Door linkage — a door-contact linkage switch mode cuts power the instant an empty room's door closes.

How the hotel occupancy sensor switch works

The sensor sees presence → the occupancy sensor switch closes the 30A relay → room powers up. Presence ends (or the door closes on an empty room) → configurable hold → circuit opens. The presence-detection switch mode is the most automatic form of room energy saving.

Specifications

Parameter Value
Voltage AC 180–250V (110V on request)
Max current 30A
Detection PIR motion or mmWave presence (breathing-level)
Linkage Door-contact input (optional)
Panel size 86 × 86 × 48 mm (29 mm in wall)
Material Flame-retardant ABS
Mounting Flush, single-gang box
Warranty 14 months

Applications

  • Guest rooms — a hotel occupancy sensor switch for card-free, forget-proof energy saving.
  • Meeting and public rooms — an occupancy sensor switch that powers down between bookings.
  • Tight-loop savings — a door-contact linkage switch that cuts power the moment an empty room is closed.

Certifications and export

CE and RoHS certified. The presence-detection switch ships with compliance documents; sampling in 7–10 days, mass production in 20–30 days via FOB Shenzhen, CIF, or DDP. OEM detection tuning and door-linkage wiring available at MOQ.

Compare presence-based control against card switches in the hotel energy saving switch buying guide.

Key selling points

Power by presence, not by card

The hotel occupancy sensor switch turns the room on when it detects a person and off after they leave — no card required, no card to lose.

PIR or mmWave detection

Choose a PIR occupancy sensor switch for low-cost motion, or an mmWave presence-detection switch for still-occupancy (breathing-level) detection.

Door-contact linkage

A hotel door sensor switch mode cuts power the moment the door closes on an empty room, the tightest energy saving loop.

30A relay with adjustable hold

Full-room 30A control with a configurable off-delay so the lights stay on through short absences.

Technical specifications

Voltage AC 180–250V
Max Current 30A
Detection PIR motion or mmWave presence
Linkage Door-contact input
Panel Size 86 × 86 × 48 mm
Material Flame-retardant ABS
Mounting Flush
Warranty 14 months

Request pricing, samples, or customization details

Leave the application, quantity, and target market information so the sales team can respond with a practical next step.

Selected product: Hotel Occupancy Sensor Switch — PIR / Radar Room Power Control
Step 1
Quick brief

Start with contact details, quantity, and the shortest useful summary of your requirement.

Step 2
Add specs and trade details

Use the optional second step when you already know destination, target terms, certifications, or packaging needs.

Contact details
Project summary
No file selected

Upload reference photos, datasheets, or requirement sheets.

Step 2
Add specs and trade details

Use the optional second step when you already know destination, target terms, certifications, or packaging needs.

Add technical details
Commercial terms
Technical requirements

The second step is optional. Submit after step one if you need to start the conversation quickly.

Structured RFQs help the team review feasibility, pricing, sample routes, and export requirements faster.

We respect your privacy. Response within 24 business hours.

Ready for RFQ

Share your product requirements and get a practical next step

Send your drawings, target quantity, and timeline. Our sales engineering team will respond within 24 business hours with a practical next step, a quote, or a sample plan.

Send a quick inquiry

Tell us what you need — room size, target volume, timeline. We respond within 24 business hours.

A clear brief helps the team reply within one business day with the right catalog, sample route, or quotation next step.