Skip to content
Hotel door card power switch, insert-card power-on and delay cut-off in a white 86-box plate
CERoHSISO 9001
Answer Snapshot

Qualification facts buyers can extract quickly

Hotel door card power switch, the classic insert-card-and-power, card-removal delay cut-off control. 16A high load handling, drives contactors for HVAC and water heaters. 220V AC. CE RoHS. OEM/ODM supplier.

Last Updated
9/5/2026
Who it is for
Hotel owners and engineering directors specifying classic card-based room power control, Electrical contractors and installers wiring guest room power circuits, New-build and renovation procurement teams for hotel projects
Use cases
Classic insert-card guest room power control for new-build hotels, High-load room circuits with HVAC and water heaters driven via contactor, Retrofit of existing rooms with a familiar, reliable card switch, Standard guest room and serviced apartment power control
MOQ
500 pcs for standard models; negotiable for OEM/ODM
Lead time
Samples 5-7 days / Mass production 15-25 days
Certifications
CE, RoHS
Served markets
Worldwide (CE/RoHS certified)
Export context
Designed for hospitality OEM ODM projects requiring CE certified guest room power control with global voltage support
Next step
Request a sample door card power switch with a contactor to validate high-load switching in your target room.

Product overview

Why choose a hotel door card power switch

A hotel door card power switch is the classic guest room power control device: insert a card to power the room, remove the card to cut power after a short delay. This insert-card-on, delay-off pattern is the most widely understood behaviour in hotel rooms worldwide, and it is exactly why a hotel door card power switch remains the dependable default for new-build and renovation projects. With a 16A high-load relay and contactor drive capability, this door card power switch handles not just lighting and sockets but also HVAC and water heaters, making it a fit for the full range of guest room electrical loads.

How a hotel door card power switch works

The behaviour of a hotel door card power switch is deterministic and familiar. On arrival, the guest inserts the key card into the slot; within 0.5 seconds the switch closes its relay and powers the room's controlled circuit — lighting, sockets, HVAC, and any other wired loads. On departure, the guest removes the card and the switch begins a selectable time-delay of 15s, 30s, or 60s before opening the relay and cutting power. That delay serves a practical purpose: it lets the guest gather belongings in a lit room, and it lets the air conditioning compressor complete a graceful shutdown rather than being cut abruptly, which protects equipment and lowers maintenance calls.

16A high-load handling and contactor drive

What sets a hotel door card power switch apart is its ability to manage larger loads. The internal relay is rated 16A resistive and 10A inductive, so the switch can carry up to 3500W of connected load directly — enough for the lighting, sockets, and typical HVAC of a guest room. For high-power equipment such as water heaters, large air handlers, or a room air-conditioning unit on its own circuit, the switch's dry contact output drives an external contactor. The contactor does the heavy switching while the switch provides the control logic, keeping switch contacts cool and extending service life even in rooms with demanding loads.

Energy saving with a delay cut-off

A hotel door card power switch delivers energy saving by ensuring controlled loads run only while a guest card is present. In a typical hotel, rooms are empty for 12-18 hours a day, yet HVAC and lighting frequently run the whole time. With a door card power switch, power drops automatically after the card-removal delay, ending that waste without depending on guest behaviour or staff reminders. The selectable delay is short enough to save energy and long enough to protect HVAC, so the switch delivers room-level savings while preserving equipment life. Engineering teams commonly measure 20-40% reductions in room electricity cost after deploying card power switches.

Key specifications of the door card power switch

This hotel door card power switch operates on AC 100-240V, 50/60Hz for global voltage support, with a 16A resistive / 10A inductive relay. Standby power draw is below 0.3W when no card is present, so the switch does not offset its own energy saving. It accepts standard IC and RFID guest key cards, comes with a flush white 86-box face plate or custom OEM finishing, and offers an optional RS485 port for centralized guest room power control and building management system upgrade paths.

Compatibility and easy installation

This door card power switch is built for friction-free installation. It works alongside any hotel door lock brand, including Onity, VingCard, Assa Abloy, and SALTO, with no integration work, and accepts standard guest cards without reissuing media. The 86-box wall mount fits standard junction boxes, so new-build teams wire it in minutes and retrofit teams replace an existing switch without rewiring the room. The dry contact output pairs cleanly with an in-room contactor for high-load circuits.

OEM and ODM capability

As an OEM/ODM supplier, we tailor the hotel door card power switch to project requirements: face plate color and logo, relay rating, power-on/power-off timing, RS485 protocol, and packaging. Minimum order quantity is 100 pcs with samples available in 5-7 days and mass production in 15-25 days. We ship worldwide on FOB Shenzhen, CIF, DDP, or EXW terms and support T/T, L/C, and Trade Assurance payment, with every unit carrying CE, RoHS, and ISO 9001 compliance.

How to get a quotation

Tell us your room count, target loads (lighting, sockets, HVAC, water heater), and whether loads will be switched directly or through an external contactor. We will return a per-room cost, wiring diagram, contactor recommendation, and sample plan within 24 business hours.

Key selling points

Insert card to power, remove card for delay cut-off

The classic hotel door card power switch behavior: the room powers on when the card is inserted and cuts power after a selectable 15s/30s/60s delay when the card is removed — the pattern most hotel guests and engineers already understand.

16A high-load handling and contactor drive

A 16A resistive relay handles standard room loads directly, while the dry contact output drives an external contactor for high-power HVAC, water heaters, and air handlers, protecting the switch and extending its life.

Delay cut-off protects HVAC equipment

The selectable card-removal delay lets air conditioning compressors shut down gracefully, preventing the short-cycling that damages compressors and drives up maintenance across a hotel portfolio.

No network required, works standalone

The door card power switch controls the room on its own, requiring no app, network, or building system, which makes it simple to specify and deploy in any guest room.

Compatible with existing door locks and guest cards

Designed to work alongside any hotel door lock brand and to accept standard guest key cards, the switch requires no integration work and no proprietary card media.

Technical specifications

Rated Voltage AC 100-240V, 50 60Hz
Rated Current 16A resistive, 10A inductive
Card Detection IC RFID insertion
Power-on Delay 0.5s after insertion
Power-off Delay 15s 30s 60s
Output Dry contact for contactor drive
Max Load 3500W direct
Contactor Drive Supports external contactor for high-power loads
Standby Power 0.3W when no
Mounting Standard 86-box wall mount
Face Plate Flush white PC custom OEM
Card Type Guest room key cards, IC RFID tags
Operating Temperature 20°C to +55°C
IP Rating IP20
Dimensions 86mm x 86mm x 36mm
Housing Fire-retardant PC, white or custom color

Request pricing, samples, or customization details

Leave the application, quantity, and target market information so the sales team can respond with a practical next step.

Selected product: Hotel Door Card Power Switch — Insert-Card Power, Delay Cut-Off
Step 1
Quick brief

Start with contact details, quantity, and the shortest useful summary of your requirement.

Step 2
Add specs and trade details

Use the optional second step when you already know destination, target terms, certifications, or packaging needs.

Contact details
Project summary
No file selected

Upload reference photos, datasheets, or requirement sheets.

Step 2
Add specs and trade details

Use the optional second step when you already know destination, target terms, certifications, or packaging needs.

Add technical details
Commercial terms
Technical requirements

The second step is optional. Submit after step one if you need to start the conversation quickly.

Structured RFQs help the team review feasibility, pricing, sample routes, and export requirements faster.

We respect your privacy. Response within 24 business hours.

Ready for RFQ

Share your product requirements and get a practical next step

Send your drawings, target quantity, and timeline. Our sales engineering team will respond within 24 business hours with a practical next step, a quote, or a sample plan.

Send a quick inquiry

Tell us what you need — room size, target volume, timeline. We respond within 24 business hours.

A clear brief helps the team reply within one business day with the right catalog, sample route, or quotation next step.